Power Quality Improvement using Shunt Hybrid Power Filter

Barai, Mili (2012) Power Quality Improvement using Shunt Hybrid Power Filter. MTech thesis.

[img]
Preview
PDF
1536Kb

Abstract

This project report presents design, simulation and development of passive shunt filter and shunt hybrid power filter (SHPF) for mitigation of the power quality problem at ac mains in ac-dc power supply feeding to a nonlinear load. The power filter is consisting of a shunt passive filter connected in series with an active power filter. At first passive filter has been designed to compensate harmonics. The drawback associated with the passive filter like fixed compensation characteristics and resonance problem is tried to solve by SHPF. Simulations for a typical distribution system with a shunt hybrid power filter have been carried out to validate the presented analysis. Harmonic contents of the source current has been calculated and compared for the different cases to demonstrate the influence of harmonic extraction circuit on the harmonic compensation characteristic of the shunt hybrid power filter.


Item Type:Thesis (MTech)
Uncontrolled Keywords:Shunt passive filter, shunt hybrid power filter, harmonic compensation, modeling.
Subjects:Engineering and Technology > Electrical Engineering
Divisions: Engineering and Technology > Department of Electrical Engineering
ID Code:3964
Deposited By:Barai Mili
Deposited On:12 Jun 2012 15:48
Last Modified:12 Jun 2012 15:48
Supervisor(s):Mohanty, K B

Repository Staff Only: item control page